Rafaqar Ahmed
Assistant Manager Projects (Electrical)
Renewable Energy Engineering (REEE) Pvt Limited - Karachi, Pakistan
خلاصہ
I am an Electrical & Instrumentation Engineer with more than five 6 years of work experience in the renewable energy projects. So far, I have participated in over 500 MW of wind and solar projects in Pakistan. Major Tasks include Project Development, Design Review, and Construction supervision, Testing & Commissioning, Inspection, Planning and HSE. Also Obtained training (Instrument & Control) in OGDCL which is leading E&P Sector and national Oil and Gas company of Pakistan
پراجیکٹس
50 MW Master Green Wind Power Limited, Pakistan
99 MW China Three Gorges Second Wind Farm Pakistan Limited
150 MW Tricon Boston Wind Power Project, Pakistan (TBCCPL)
50 MW Hawa Wind Power Limited, Pakistan
50 MW Master Wind Energy Limited, Pakistan (MWEL)
30 MW Tapal Wind Energy Private Limited, Pakistan (TWEPL)
50 MW Gul Ahmed Wind Power Limited, Pakistan (GAWPL)
I am an Electrical & Instrumentation Engineer with more than six 6 years of work experience in the renewable energy projects. So far, I have participated in over 500 MW of wind and solar projects in Pakistan. Major Tasks include Project Development, Design Review, and Construction supervision, Testing & Commissioning, Inspection, Planning and HSE. Also Obtained training (Instrument & Control) in OGDCL which is leading E&P Sector and national Oil and Gas company of Pakistan.
<p><strong><span lang="EN-GB">Detailed Tasks Assigned on the Projects</span></strong><strong><span lang="EN-GB">:</span></strong></p>
<ul type="disc">
<li>Oversaw project development in the renewable energy sector under Renewable Energy Policy 2006.</li>
<li>Coordination with <span lang="EN-GB">the government agencies</span> CPPA, NTDC (Design, Protection & Control and Telecom) and NPCC.</li>
<li>Managing design approvals of the equipment and drawings from CPPA-GL,NTDC & NPCC</li>
</ul>
<ul type="disc">
<li>Coordination with EPC contractor, Sub-Contractor and design consultant.</li>
<li>Technical advisor on electrical design during Energy Purchase Agreements (EPA) and Engineering, Procurement and Construction (EPC) contract negotiations for renewable power projects.</li>
<li>Design review of Electrical drawings & technical documents of all electrical.</li>
<li>Review & preparation of Quality Inspection plan, testing and commissioning plan to fulfill requirements of EPC and Energy Purchase Agreement (EPA)</li>
<li>Construction Supervision and inspections of all electrical related equipment.</li>
<li>Witness the Testing & commissioning of all electrical related equipment.</li>
<li>Scheduling, planning & management of the electrical related assignments</li>
<li>Reviewing the progress reports submitted by EPC Contractor on a regular basis.</li>
<li>EHS Training “Working at Height & Rescue Training” Goldwind International</li>
<li>HSE Training “ Permit to work Training” Pak Safety Solution</li>
</ul>
99 MW China Three Gorges Second Wind Farm Pakistan Limited
Responsibilities:
• Ensure compliance of Energy Purchase Agreement (EPA).
• Coordination with CPPA, NTDC (Design, Protection & Control and Telecom) and NPCC.
• Coordination with EPC contractor, Design consultant.
• Approval of the equipment specification, drawings and layout design from CPPA/NTDC.
• Design review and CPPA/NTDC approval of following Electrical drawings & Technical Data.
Overall SLD and Protection Metering SLD
132 KV Switchyard Layout
50 MVA Power Transformer Specification and its Accessories.
132 KV Switchgear Specification and Type Test Reports
132 KV CT/VT Specification and Type Test Reports
132 KV Surge Arrestor Specification and Type Test Reports
132 KV Metering CT/VT and Metering Panels Specification and Drawings
Protection Relays and Control System and Monitoring Equipments Specification and Drawings
Telecommunication Equipments (SDH, PABX, Tele-Protection} Specification and Drawings
• Factory Acceptance Test (FAT) Of Following Equipment
132 KV CT & CVT (Sieyuan - Jiangsu Hertz Instrument Transformer Co., Ltd. China)
132KV Metering CT & CVT (Sieyuan - Jiangsu Hertz Instrument Transformer Co., Ltd. China)
132 KV Circuit Breaker and Disconnectors (Sieyuan - Jiangsu Rugao High Voltage Electric Co., LTD China)
• Site Acceptance Test (SAT) Testing and Commissioning
60 & 50 MVA Power Transformers , 132 KV Switchgear (AIS), 132 KV CTs & CVTs, 132 KV Surge Arrester, 33 KV GSU & RMU , 33 KV MV Switchgear, Protection Relays (Siemens 7UT613, 7SD522, 7SS85, 7SJ804), Bay Control Unit – BCUs (Siemens & Sifang),
150 MW Tricon Boston Wind Power Project, Pakistan (TBCCPL)
Key Responsibilities:
• Getting clear understanding of scope of work from contract.
• Co-Ordination with client, contractors and sub-contractors.
• Implement & enforce all company policies, procedures and practices.
• Reviewing all project related activities & preparing all project related reports on site.
• (Quality Assurance / Quality Control) QA/QC Documentation
• Supervise and Monitor all the electrical erection/installation activities.
• Responsible for Project, Plant management and QHSE requirements.
• Attending weekly and monthly meeting with company and present progress reports.
• Prepares quality procedure, inspections and test plan checklist and documentation.
Testing, Pre-commissioning and Commissioning:
• 31.5/40/50 MVA Power Transformer
• 132 KV Switchgear (GIS) Toshiba-China
• 132 KV Switchgear (AIS) Sieyuan - Jiangsu Rugao H-V Electric
• 132 KV Current Transformers (CT) & VT/CVT Capacitance Voltage Transformers (CVT)
• 132 KV Surge Arrester
• 33 KV Switchgear
• MCR high voltage Static var compensation device (MSVC)
• WTG Transformer, Auxiliary Transformer, Grounding Transformer
• Cable (LV Control , LV & MV Power cable) and Earthing Resistance
• Protection Relays (Schneider Electric P-632, P-543, P-746, P-141)
• Bay Control Unit (Schneider Electric BCU C264)
Trainings
• Power Transformer (SANBIAN SCI-TECH CO.LTD)
• 132 KV Switchgear (AIS) Sieyuan & GIS (Toshiba)
• MV Switchgear (ABB Company)
• MCR (Shandong Taikai Power Electronic Co. Ltd )
• Protection Relays (Micom P-632, P-543, P-746, P-141Schneider Electric )
• E-BOP SCADA (Schneider Electric )
• WTG SCADA (GE Power & Water)
ESH “Working at Height & Rescue Training
Goldwind International
Key Responsibilities:
• Getting clear understanding of scope of work from contract.
• Co-Ordination with client, contractors and sub-contractors.
• Implement & enforce all company policies, procedures and practices.
• Reviewing all project related activities & preparing all project related reports on site.
• (Quality Assurance / Quality Control) QA/QC Documentation
• Supervise and Monitor all the electrical erection/installation activities.
• Responsible for Project, Plant management and QHSE requirements.
• Attending weekly and monthly meeting with company and present progress reports.
• Prepares quality procedure, inspections and test plan checklist and documentation.
Testing, Pre-commissioning and Commissioning:
• 31.5/40/50 MVA Power Transformer
• 132 KV Switchgear (GIS) Toshiba-China
• 132 KV Switchgear (AIS) Sieyuan - Jiangsu Rugao H-V Electric
• 132 KV Current Transformers (CT) & VT/CVT Capacitance Voltage Transformers (CVT)
• 132 KV Surge Arrester
• 33 KV Switchgear
• MCR high voltage Static var compensation device (MSVC)
• WTG Transformer, Auxiliary Transformer, Grounding Transformer
• Cable (LV Control , LV & MV Power cable) and Earthing Resistance
• Protection Relays (Schneider Electric P-632, P-543, P-746, P-141)
• Bay Control Unit (Schneider Electric BCU C264)
Trainings
• Power Transformer (SANBIAN SCI-TECH CO.LTD)
• 132 KV Switchgear (AIS) Sieyuan & GIS (Toshiba)
• MV Switchgear (ABB Company)
• MCR (Shandong Taikai Power Electronic Co. Ltd )
• Protection Relays (Micom P-632, P-543, P-746, P-141Schneider Electric )
• E-BOP SCADA (Schneider Electric )
• WTG SCADA (GE Power & Water)
ESH “Working at Height & Rescue Training
Goldwind International
سرورق تبدیل کریں
زوم:
Beware! Reported Companies
Rozee.pk is not in business with below-mentioned companies due to multiple fraudulent recruiting
complaints/activities which begun with fictitious interview inquiries sent by instant message (IM), email, or
text. If the employer asks you to pay money for any purpose including processing to shortlisting, please
immediately report at support@rozee.pk.
Dewan Global
SA Parco Group of Companies
Crystal Group of Companies
Advance Superior Group USA
Techium Solution
Royal Indus Group
Pak Adam Group
Day & Night Recruitment Agency
Umair Property Marketing
Easysearch.pk
Saigol Group of Companies
Pak United Arab Group
Supreme Group of Companies
HA Group of Companies
Etihad Group of Companies
KP Group of Companies
Vital Group of Companies
AR Enterprises
Delta Group of Companies
Ultimate HR Solution
World International LLC
AJL Group of Companies
Bestland Group
Bizlinks
Lexer Group of Companies
Fragrance Land Pvt Ltd
Khawaja Group of Industries
EBS (Earn Be Smart) Pvt Ltd
Jamal Group of Industries
Jamal Mirza Group of Company
Pro Hirez
Kwality Surgical
Kwality Group
Easy Search Pvt Ltd
Shah International Technical Training Institute & Consultants Pvt Ltd