خلاصہ

Experience on Huawei, Ecrssion and Motorola equipment’s with outstanding success rate on 2G,3G,4G Performed Indoor & Outdoor, Walk Tests and Drive Test of LTE, UMTS using GENEX Probe v3.14 & TEMS 16.1.1, TEMS 16.3 including static and dynamic test to check the reliability of the site and TRANSMISSION Network installation, operation, maintenance and support. Highly experience in installation coordination with telecommunication operator, vendor and subcontractor.
DT Engineer at

TurnoTech Pakistan

BSS & Microwave Engineer at

Spine Engineering Pvt Lmtd- Huawei Subcone

Crystal Engineering Pvt. Limited- Huawei Subcon

تجربہ

کمپنی کا لوگو
FM Engineer
Motorola Solutions
ستمبر ۲۰۱۸ - موجودہ | Muscat, Oman

Lead and manage the Facilities Management service provider to provide facilities engineering/management activities, the functional operations of the facilities and maintenance service and support. Facilities services include corrective, preventive and predictive maintenance.
• Investigates malfunctions or breakdowns of systems to diagnose causes and locate the source of the problem.
• Ensure PM schedules are adequate and timely.
• Responsible for the provision of weekly / monthly reporting to the client
• Assist with operations maintenance activities as necessary.
• Knowledge of maintenance best practice systems
• Manage and approve work schedules and time off requests while upholding 24/7 coverage requirements
• Responsible for Ericsson Enode B RBS6601 configuration , Software upgrade
Motorola using B20 band
• SiteBoss by ASENTRIA (™ 550 Remote Site Manager) configuration and alarm handling as per designed. Manage the Site Boss for handling by 19 different type of alarm by customer needed, test and identify the problem including the auto mode function for control the Generator.
• Ericsson Traffic node R5 configuration by auto configuration using CLI tools script loading, and manage for link alignment
• Security CCTV camera configuration-test the camera for re align with Site Boss for LIVE traffic and recording of the previous activities at the shelter.
• Eltek rectifier integration and commissioning – to make sure all the system control by smart controller in rectifier handling the alarm and instruction to given correct value of the supplying to the all equipment.
• Extreme switch configuration and integration – script loading and test all the ports used to make sure all the equipment Enode B, TNode, Site Boss, Eltek rectifier, camera and Generator can access via switch.

کمپنی کا لوگو
DT Engineer
Gulf Telecommunications
نومبر ۲۰۱۷ - اگست ۲۰۱۸ | Muscat, Oman

Performed Indoor & Outdoor, Walk Tests and Drive Test of LTE, UMTS using GENEX Probe v3.14 & TEMS
16.1.1, TEMS 16.3 including static and dynamic test to check the reliability of the site.

کمپنی کا لوگو
DT Engineer
TurnoTech (Pvt.) Ltd.
مارچ ۲۰۱۷ - ستمبر ۲۰۱۷ | Lahore, Pakistan

• Performed Indoor & Outdoor, Walk Tests and Drive Test of LTE, UMTS using GENEX Probe v3.14 & TEMS 16.1.1, TEMS 16.3 including static and dynamic test to check the reliability of the site.
• Hands on experience with 3G,4G IBS Walk Testing Good drive testing knowledge along with parametric knowledge of Ericsson and Huawei (RXLEVEL, RXQUAL, C/I, TA, RSCP, ECNO, SC, RSRP, RSRQ, SINR and Throughput) for 2G, 3G and LTE Sites.
• Indoor and outdoor Customer complaints. Follow up and solve customer complaints by Implementing Soft/Hard Optimization WOs in order to maintain high quality service to company customers.
• LTE Testing including CSFB incoming and outgoing, HTTP & FTP Downloading and Uploading, PDP activation and deactivation, PING, Cell reselection and TAC update.
• Coordination with RAN Team in case of any issue on site like CS IRAT & RRC Rejection,SMS failure or DN, HO/RA Update failure, CS Fall Back.
• Troubleshooting on field Issues and provide technical Support to L-I to resolve the issues in timely manner
• Troubleshoot RF related problems such as poor coverage/Static KPIs, hardware faults, missing neighbors, call failures, HO failures, bad quality
• DT Log File Analysis, identification and reporting of issue promptly from field
• Tracking Illegal jammers using Net Tektronix YBT 250 Interference Analyzer
• Responsible for removing illogical serving or bad SINR/RSRP/RSRQ patches & checking swap among sectors

کمپنی کا لوگو
Survey Engineer
Capital Survey
ستمبر ۲۰۱٦ - فروری ۲۰۱۷ | Abu Dhabi, United Arab Emirates

• Site survey and reporting
• Determination of Antenna Height and Orientation.
• Conduct and Manage line of sight survey for Microwave Links.
• Determination of azimuth angle towards the far end & MW antenna height

کمپنی کا لوگو
Survey Engineer
Anderomedia Engineering
فروری ۲۰۱٦ - اگست ۲۰۱٦ | Islamabad, Pakistan

Site survey and reporting (LTE1800, 4G,3G,2G,U900 also Microwave).
* RF survey for testing the feasibility and installation of the system.
* Site selection for achieving optimum coverage in required geographical area by collecting Hot Spots.
* Determination of Antenna Height and Orientation.
* Conduct and Manage line of sight survey for Microwave Links.
* Determination of azimuth angle towards the far end & MW antenna height.
* Checking the obstacles, AMSL variation & Clutter on the LOS by route track method.
* Map study and preparation of path profiles (Path loss, terrain data).

کمپنی کا لوگو
BSS and TXN Engineer
Spine Engineering (Pvt) Ltd
دسمبر ۲۰۱۳ - فروری ۲۰۱٦ | Lahore, Pakistan

Key Responsibility Areas
• Installation of TP-4800 BTS and ICC 500 (power cube)
• Installation of Battery Banks
• Installation of CCTV cameras
• DVR installation, IPs to cameras, configurations, Troubleshooting,
• Perform Commissioning, Configurations, Integration of Huawei TP-4800 BTS and Transmission Equipment
• Coordination with Customer Persons about Site Activities
• Budgeting for the Swap Activity
• Planning and Conducting TSSR, Swap activity, E1and Vlan Clearance
• Worked on NEC Pasolink and ZTE Transmission Equipment
• Perform Installation, Configurations, Integration of Huawei RRU 3004,3008,3839,3936
• Worked on RTN 600,905 and 310 and 380
• Accomplishing ATP and Drive Test (DT)
• Site survey and reporting (LTE1800, 4G,3G,2G,U900 also Microwave).
• In hands site master experience to calibrate and check VSWR ,DTF VSWR
• Rectification of VSWR alarms & BSS Alarms clearance
• 2G,3G and 4G complete site installation expert
• M/W links commissioning [1+0, 1+1 HSB, 1+1 , XPIC (1 + 1 HSB)
• Hand on Experience of WEB LCT

کمپنی کا لوگو
Asst.coordinater & BSS Engineer
Crystal Engineering
جون ۲۰۱۳ - نومبر ۲۰۱۳ | Lahore, Pakistan

Key Responsibility Areas
• Responsible of all Quality Aspects according to ufone Requirement
• Train the teams about ufone Quality Standards
• Spot check of sites to verify any type of issue
• Random visits of different sites for inspection of quality work
• On spot removal of quality snags
• Coordination with customer for any variation in the standards
• Conducting PAT documents of sites according to customer requirement
• Updating of weekly progress reporting to higher management
• Regular meetings with customer about PAT activities and quality improvement

تعلیم

Hazara University, Dodhial
بیچلرز, بیچلرز ان ٹیکنالوجی, Telecommunication Engineering‎
Optical fiber, Microwave, Antenna
CGPA 2.6/4
2013

پیشہ ورانہ مہارتیں

ماہر Maintaining Safety Standards

زبانیں

ماہر اردو
ماہر انگریزی

آپ کن کمپنیز کی پیروی کر رہے ہیں